Add to Cart
*Note:Characteristics subject to change without notice.
*Software Protection including:
1.Over Charge Voltage Protection;
2.Over Charge Current Protection;
3.Over Discharge Voltage Protection;
4.Over Discharge Current Protection;
5.Charge Over Temperature protection;
6.Discharge Over Temperature protection;
* Voltage/Temperature Calibration:During operation after calibration, The difference for Battery Pack's voltage must<±40mv;The difference for single cell's voltage must<±20mv,the difference for the Temperature must<±1°C;
No. | Items | Range | Parameters | Note |
1 | COV Threshold (mV) | 3700-5000 | 4300 | |
2 | COV Recovery (mV) | 0-4400 | 4150 | |
3 | CUV Threshold(mV) | 0-3500 | 2700 | |
4 | CUV Recovery (mV) | 0-3600 | 3000 | |
5 | OC (1st Tier) Chg (A) | 0-20 | 6 | |
6 | OC (1st Tier) Dsg(A) | 0-20 | 6 | |
7 | Current Recovery Time(S) | 0-240 | 8 | |
8 | Over Temp Chg | 0-120 | 60.0 | |
9 | OT Chg Recovery | 0-120 | 55.0 | |
10 | Over Temp Dsg | 0-120 | 65.0 | |
11 | OT Dsg Recovery | 0-120 | 60.0 | |
12 | Fast Charge Current(mA) | 2500 | ||
13 | Charging Voltage(mV) | 12600 | ||
13 | Design Capacity(mAH) | 0-65535 | 4400 |
Setting Programmable Options
The TI Chip data flash comes configured per the default settings detailed in the chip data sheet.
Ensure that the settings are correctly changed to match the pack and application for the chip solution being evaluated.
The programming connection as below:
IMPORTANT: The correct setting of these options is essential to get the best performance.
The settings can be configured using the Data Flash screen.
P.S.: All the products from BesTech Power are well programmed and Calibrated.
To adjust all the parameters on the PC/Laptop:
(The screen shot of software on PC)